|
In this article 1. Why litres per person is a rough guide only 2. Start from the peak hour, not the daily total 3. The rental and social housing pattern 4. Tank volume against recovery time 5. Measure the site before the volume is fixed 6. Questions buyers ask most Related reading: storage electric water heater range Product overview: electric water heater product range Capacity for projects: project water heater supply |
|
Quick answer: Litres per person is a starting point, not a rule. For a temperate market with one shower each, 30 to 40 litres of tank per person at 3 kW is workable; for a rental flat with a single tenant and a low power connection, 50 litres at 2 kW is often the better commercial choice because it fits the wiring and the wall. Size the tank against peak hour demand and recovery time, then check the installation space and the electrical supply, and only then fix the volume. |
Why litres per person is a rough guide only
The familiar rule of thirty to forty litres per person comes from European domestic practice in the 1990s and assumes a temperate inlet, one daily shower per person and a tank that is reheated overnight. Turn any of those assumptions and the number changes. A market with 32 degree inlet water needs less energy per litre to reach temperature, so a smaller tank can serve more people; a market with 8 degree inlet water and long pipe runs loses more heat on the way to the tap, so the tank has to be bigger or better insulated.
The rule is useful for a first check and dangerous as a specification. A buyer who orders 100L tanks for a five person household in a cold region because forty multiplied by five is two hundred and then rounded down will spend the next two years handling complaints about cold showers in winter.
Start from the peak hour, not the daily total
A tank only has to cover the busiest hour, not the whole day, because it reheats between peaks. That single insight changes the calculation and usually reduces the size.
Take a four person household where everyone showers between seven and eight in the morning. Each shower uses roughly 40 litres at 40 degrees, mixed down from 65 degree stored water, so the hot water drawn is about 25 litres per shower at tank temperature. Four showers in one hour is 100 litres of stored hot water, plus what the element reheats during that hour.
Table: peak hour draw and a starting tank size at 3 kW, 65 degree storage
| Household pattern | Peak hour draw at tank temperature | Tank suggestion at 3 kW | Note |
|---|---|---|---|
| 1 person, 1 shower, morning | 25-30 L | 50 L | Smallest practical size for wall mounting |
| 2 people, 2 showers, morning | 50-60 L | 80 L | Most common family size in temperate markets |
| 4 people, 4 showers, morning | 95-110 L | 100-120 L | Check wall strength and door width |
| 4 people, showers spread over 3 hours | 60-75 L | 80 L | Recovery covers the spread, tank can be smaller |
| 6 people, 2 bathrooms used at once | 140-170 L | 150-200 L | Consider two tanks or a cascade bank |
The table assumes 65 degree storage and a 40 degree shower. Raise the storage temperature and the draw per shower falls, but scaling and the risk of scalding rise with it, so most suppliers settle at 60 to 75 degrees and let the mixer do the rest.
The rental and social housing pattern
Rental stock behaves differently from owner occupied housing in three ways, and each of them pushes the specification in a direction a domestic buyer would not expect.
- Tenants are transient, so the unit has to be simple enough that nobody needs a manual. A mechanical thermostat with a clear dial beats a programmable panel in this segment.
- Turnover creates demand peaks when a flat is re-let and cleaned, and that peak often coincides with a morning inspection.
- Maintenance access is poor. A unit mounted in a cupboard with no service valve will be replaced rather than repaired, which shifts the cost calculation towards reliability over purchase price.
A 50 to 80 litre tank at 2 to 3 kW is the workhorse of this segment in most markets, because it fits a standard wall, runs on a normal circuit and can be swapped by one technician in an hour. Where the building has a central riser and a landlord who wants one access point, a small cascade of two 80 litre units is often cheaper to own than one 200 litre unit that nobody can move.
Quantity planning matters as much as size. A landlord replacing 200 units will care about carton volume and pallet count, which is a question the storage electric water heater range answers per model, and about spare parts availability five years out, which is a question worth asking before the tender closes.
Tank volume against recovery time
Volume and power are a pair. Fix one without the other and the product disappoints in a predictable way.
A 100 litre tank at 3 kW recovers roughly 45 litres of 65 degree water per hour from a 15 degree inlet, so a morning peak that empties the tank leaves the second bather waiting about forty minutes. The same tank at 5 kW recovers about 75 litres per hour and the wait drops to twenty minutes, but the circuit has to carry the current. Raising the tank to 150 litres keeps the 3 kW element and buys roughly one more shower before the wait begins.
Table: recovery, current and the household each combination suits
| Tank | Element | Approx recovery from 15C inlet | Circuit at 230V | Best fit |
|---|---|---|---|---|
| 50 L | 2 kW | 25 L per hour | 10 A | Single tenant, small flat |
| 80 L | 3 kW | 45 L per hour | 16 A | Small family, rental flat |
| 100 L | 3 kW | 45 L per hour | 16 A | Family with spread out use |
| 150 L | 3 kW | 45 L per hour | 16 A | Family with morning peak, weak supply |
| 200 L | 6 kW | 90 L per hour | 32 A dedicated | Large family or small guest house |
The commercial lesson is simple: where the electrical supply is fixed and cannot be upgraded, buy volume; where the wall space is fixed, buy power. Where both are fixed, buy insulation, because a well insulated tank loses less overnight and behaves like a slightly larger one.
Measure the site before the volume is fixed
Three measurements eliminate most returns in this category, and all three can be taken by the installer in ten minutes.
- Wall to wall space including the pipe connections and the service valve, not just the tank diameter.
- Door and stair width on the delivery route, which rules out 200 litre units in many refurbishments.
- Available circuit: breaker rating, cable cross section and whether an earth leakage device is fitted.
Add the inlet water temperature range for the region and the hardness, because hard water at high storage temperature scales an element quickly and effectively reduces the volume of usable hot water over time. In hard water areas a slightly larger tank with a lower storage temperature and a magnesium anode on a short replacement cycle outperforms a small tank running hot.
Questions buyers ask most
Is a bigger tank always safer
No. A bigger tank costs more to buy, more to ship, more to heat and more to replace, and it takes longer to reheat after a full draw if the element stays the same. Oversizing is a real commercial error, not a conservative choice.
Can one model cover both a family and a rental market
An 80 litre unit at 3 kW covers both in most temperate markets, which is why it is the most common single SKU in a distributor's range. Range discipline beats breadth: three sizes, one element platform and one control board keep stock, spares and training simple.
Does insulation really change the recommended size
It changes overnight losses, which matter when the tank is reheated once a day. A tank with 40mm foam loses noticeably less than one with 20mm, so in cold climates the better insulated unit can be one size smaller and still deliver the same morning experience.
|
Send us the household pattern and the available circuit and we will return a tank and element proposal |
Related reading
electric water heater models for family and project supply
|
Author: Technical Support Team, Zhongshan ANTO Electric Appliance Co., Ltd. Electric water heater manufacturing since 2005. Published: 5 November 2026 | Last updated: 5 November 2026 Volume recommendations depend on inlet temperature, draw pattern and local electrical limits. Confirm with the installer before ordering. |



